Cooling your telescope down · Step 4 of 4
Why focus runs away from you by midnight
In a sentence: The tube shrinks as it cools and pulls the mirror closer to the camera. It isn’t your focuser slipping: it’s largely the metal.
The tube shrinks
As the temperature drops, the tube contracts and the distance between mirror and sensor changes. On an aluminum tube the effect is noticeable over a normal night; on carbon fiber, far smaller, because it barely expands at all.
The tube isn’t the only culprit (the glass and the focuser itself change too), but it’s the one you notice. That’s why focus drifts even when you touch nothing, and why at two in the morning the stars aren’t the ones you had at eleven.
How often to refocus
Capture software automates it with a temperature trigger: when ambient drops a set number of degrees, they refocus on their own. The values people use in practice run between 1 and 3 °C.
If you focus by hand, the rule is the same: every time the thermometer drops a couple of degrees, put the Bahtinov mask back on. And certainly whenever you change target.
But there’s something that changes the routine and almost no guide mentions: focus runs fast in the first hour and then settles down. That’s no coincidence. The tube shrinks in proportion to the degrees it still has to lose, so it moves a lot when you’ve just brought it out, and hardly at all at three in the morning. It’s the same curve this whole guide is about, seen from the focuser.
In practice: stay on top of focus for the first hour; after that, checking now and then is enough. And if you can afford to set up well ahead of time, you skip precisely the bad stretch.
TipIf your gear has no motorized focuser, line your refocusing up with target changes or with dithering: that way you don’t lose frames to stopping.
Carbon fiber: two sources, two conclusions
On whether carbon fiber fixes the problem, there’s disagreement. Roland Christen, of Astro-Physics, is credited with the point that on a refractor carbon can make focus shift worse, because the lens itself changes focal length with temperature and an aluminum tube’s expansion partly cancelled that out (we’ve seen this quoted on forums, not on his own site). The measured run on the 11-inch Celestron, which is a mirror telescope, suggests instead that a carbon tube cuts down the refocusing, though that’s one logged night.
Both can be true at once: it depends on whether there’s a lens to compensate for.
The routine, and the clash with dew
Here’s the conflict this guide and the dew one have to settle together: setting up early is best for cooling and worst for dew. The longer the glass spends looking at the sky, the colder it gets and the sooner it fogs up.
How to have both:
- Store the gear cold: a garage, a shed, a carport. If the tube is already at 10 °C (50 °F), there’s nothing to cool and you save the hours.
- Bring the tube out early and put the dew shield on from the start: it starts cooling while you block part of the sky the optics radiate to.
- Switch the dew heaters on from the start, on low. Preventing dew is far easier than clearing it.
- Start the fan the moment you set up, not when you’re about to begin.